In short: A Castle Hill lock-up inspection in March 2025 recorded a box gutter without an expansion joint, an upturn not properly formed and a sump that changed direction.

Why box gutters fail

A box gutter sits inside the roof footprint. When it overflows or leaks, the water ends up inside the house.

Expansion joints

Long runs of metal gutter expand and contract. Without an expansion joint the seams work loose.

Upturns

The gutter edge against a wall needs a proper upturn so water cannot ride up and over it.

Sumps

The sump should discharge straight down to the outlet. A sump that turns the water slows it and invites overflow.

Book lock-up for these designs

Once ceilings go in, box gutter faults show up only as stains.

Written by our local inspection team from work carried out in Castle Hill. Licensed building practitioners, NSW Fair Trading licence 366177C.

Guides

More new construction stage inspections guides for Castle Hill

All guides →

Book a building inspection in Castle Hill

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Castle Hill owners ask about this

Do all homes have box gutters?

No. They come with parapets and some flat roof designs.

Is lock-up the right time?

Yes. The roof is on but the details are still open to see.

What else is checked at lock-up?

Bracing, sarking, window flashings and ducting.

Is the roof itself checked?

Where it is safe, or with a drone.